Description:

The TECO® Ultra Sensitive Cyprinid Vitellogenin ELISA kit is a very sensitive enzyme linked immunosorbent assay for the quantitative determination of vitellogenin (VTG) in cyprinid fish mucus or cell culture*.

Cyprinid Vitellogenin ELISA, Perch (Perciformes) Vitellogenin ELISA

Vitellogenin determination is one of the core endpoints in screening and testing for endocrine disrupting chemicals standardized in the OECD Guidlines for the testing of chemicals for estrogenic activity:

  •   OECD (2009), Test No.229
  •   OECD (2009), Test No.230
  •   OECD (2011), Test No.234

Vitellogenin determination is used in ecotoxicological studies to determine the effects of estrogenic compounds in the water.

Assay Measuring Range: 0-2.0 ng/ml

Assay Sensitivity: < 0.03 ng/ml

Incubation time: Overnight 16-24 hours / 4h±10 min

Sample Volume: 50 µl

Sample Preparation:

  • Mucus: Collect as described in the TECO® Mucus Collection Set (TE1034). Mucus containing swabs can be stored several months at <-20°C.
  • Cell culture: Store fresh samples immediately after collection at <-20°C until assayed.

Reference Values:

  • Mucus levels are in the range of ng/ml.

*Additional assay validation may be required with the use of cell culture samples.

Kit Composition:

Kit Contents:

  • Antibody Coated Microassay Plate: 96-well plate (12×8 break-apart well strips coated with IgG directed against Cyprinid VTG)
  • Standard Stock Solution: 35 ng, 2 vials
  • Control C1:  low control, 2 vials
  • Control C2: high control, 2 vials
  • Wash Buffer: 1 x 30 ml, 50X . Dilute 1:50 with deionized water.
  • Dilution Buffer: 1 x 55 ml. Ready to use.
  • Matrix Solution: 1 x 7 ml. Ready to use.
  • Biotinylated Antibody (Biotin-AB): 1 x 12 ml. Ready to use.
  • Streptavidin Peroxidase Conjugate (SA- HRP Conj.): 1 x 12 ml. Ready to use.
  • TMB Substrate: 1 x 12 ml. Ready to use.
  • Stop Solution: 1 x 12 ml 1M HCl. Ready to use.

Materials required but not supplied:

Pipettes, 10 μl – 1000 μl
• Multichannel Pipettes , 50 μl – 100 μl
• Graduated cylinders for reconstituting and diluting reagents
• Manual Aspiration System or automatic washer for ELISA plates
• Distilled water
• Vortex mixer
ELISA plate reader suitable for 96 well formats and capable of measuring at 450 nm (Reference: 590-650 nm).
For extended standard range: ELISA plate reader suitable for 96 well formats and capable of measuring at 405 nm and 450 nm (Reference: 590-650 nm)
ELISA plate shaker (500 rpm)
• Software package for data generation and analysis

For mucus samples: The Mucus Collection Set (TE1034) which includes Extraction Buffer and validated Sampling Swabs is also required.

Assay Principle:

Assay Principle

The TECO® Ultra Sensitive Cyprinid Vitellogenin ELISA kit is a 96 well immuno-capture ELISA product. Samples are incubated with the vitellogenin specific antibody coated microtiter plate. After unbound material is washed out, a polyclonal biotinylated antibody binds to the vitellogenin. In the following incubation step, a streptavidin-peroxidase conjugate binds to the biotinylated antibody. In the final substrate reaction, the color development is directly proportional to the amount of vitellogenin in the sample.

Result Analysis

The standard range of the assay is between 0.025 and 2.0 ng/ml. A calibration curve can be established by plotting standard concentration on the x-axis (linear scale) against the absorbance of the standards on the y-axis (linear scale). The vitellogenin concentrations can then be read off the calibration curve. A 4-parameter curve fit should be used for automatic data reduction. If samples were pre-diluted, the concentration will be obtained by multiplying the value read off the calibration curve by the dilution factor. Note that the dilution correction for mucus is not necessary if only the 0.5 ml Extraction Buffer was added to the swab. Samples with higher absorbance values than Standard A should be re-tested after diluting with Dilution Buffer and then this additional dilution should be taken in account for the concentration calculation.

Ultra Sensitive Cyprinid VTG ELISA Standard Curve

TECO® Ultra Sensitive Cyprinid VTG ELISA Standard Curve Example

Species:

  • Carp (Cyprinus carpio)
  • Goldfish (Carassius gibelio auratus)
  • Zebrafish (Danio rerio)
  • Fathead minnow (Pimephales promelas)
  • Common bream/freshwater bream/bronze bream/carp bream (Abramis brama)
  • Roach (Rutilus rutilus)
  • Common rudd  (Scardinius erythrophthalmus)
  • Chub (Squalius cephalus)
  • Common nase  (Chondrostoma nasus)
  • Bleak (Alburnus alburnus)
  • Neon Tetra (Paracheirodon innesi)
  • Gudgeon (Gobio gobio)
  • Common dace (Leuciscus leuciscus)
  • Stone loach (Barbatula barbatula)
  • Common minnow (Phoxinus phoxinus)

Background:

In oviparous animals, vitellogenin (VTG) is an estrogen-induced yolk precursor protein mainly synthesized in the liver to be deposited in the maturing oocytes, where it is split in the yolk proteins lipovitellin 1, lipovitellin 2 and phosvitin. These yolk proteins serve as nourishment storage for the developing embryos. Non-physiological induction of vitellogenin in males or in juvenile fish is thought to indicate an estrogen mediated endocrine disruption. Therefore, VTG determination is one of the core endpoints in screening and testing for endocrine disrupting chemicals standardized in the OECD Guidelines for the testing of chemicals for estrogenic activity. Normally, vitellogenin is measured in blood samples or whole body homogenate (WBH) – but both sample types require invasive and destructive treatment of the fish. Blood can be difficult to collect, in particular where very small fish are concerned and where the animals must survive sampling.

Recently, several cell types have been shown to produce VTG after estrogen stimulation, including those of the epidermal mucosa. Even though the VTG concentration in the skin mucus is an order of magnitude lower than in blood serum or in body homogenates (containing liver tissue), the skin mucosa is very well suited as a matrix for determining exogenous VTG induction caused by environmental chemicals with affinity to estrogen receptors. By using a highly sensitive ELISA in combination with a unique sampling and extraction system the determination of mucosa-born VTG determination has the following advantages:

  • Simple and highly standardized sampling technique and sample preparation.
  • Strictly defined matrix without protease contamination caused by non-target tissues or lymphatic fluid.
  • Non-destructive and thereby allowing several subsequent samplings in order to record a kinetic of VTG induction with a maximum known to appear after 7 days of exposure. Therefore Mucosa test are fully compatIBLe with acute as well as chronical OECD test methods.
  • Epithelial organized epidermis is directly exposed to exogenous estrogens and thereby allowing a direct comparison with in vitro test using estrogen sensitive vitellogenin producing fish cell lines.
  • Lower degree of interference with endogenous VTG production (in females) and bio concentration or enterohepatic circulation of the effective estrogen (xenoestrogen) and thereby showing a clear dose response relationship.
  • StABIlity of standards and samples if prescribed storage conditions are observed.

The TECO® Ultra Sensitive Cyprinid Vitellogenin ELISA kit provides a high-sensitivity ELISA option for researchers determining VTG protein concentration in fish mucus or cell culture samples.

品牌介绍

Mission Statement

Diapharma Group, Inc. in West Chester, Ohio sells hemostasis, thrombosis, platelet function testing, instrumentation, and apoptosis products in the diagnostic and research fields and provides strong technical competence and experience to ensure customer expectations will be met or exceeded.

diapharma hemostasis chromogenic clotting elisa assay test kit

 

History

The Diapharma Group, Inc. formed on January 1, 1997 from Pharmacia Hepar, Inc. in Franklin, Ohio, and began as the exclusive US and Canadian distributor of the Chromogenix substrates and assays.

Over a quarter-century ago, Chromogenix developed the first chromogenic substrate technology under the former name, Kabi Diagnostica. Kabi later merged with Pharmacia. Some of Diapharma’s current staff worked inside the Chromogenix department within Pharmacia’s heparin manufacturing plant.

In 1998, Diapharma moved to West Chester, Ohio, where it remains today. Over the years, Diapharma expanded its product line to include a variety of hemostasis, cell death, platelet function, ecotoxicology, assays, reagents, antibodies and instruments from superior manufacturers.

In 2017, Diapharma celebrated twenty years of success


自营商城图标
厂家直采
全球直采模式 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔
在线客服
客服电话

4000-520-616

微信交流